GH HILCOFLEX PU DRAG bound with Storz clamping ring | © GH

Storz Segment binding

Tipps & Tricks

Mounting video

Assembly video

See step by step in the video how the binding in hose size A 110 with the Storz slide ring succeeds and what must be observed: 

 

  • Cut hose cleanly and straight.
  • Push the hose onto the spigot at right angles to the coupling.
  • Open the clamping ring and position it over the hose.
  • Distance between clamping ring and clamp part = approx. 7 mm.
  • Tighten all screws evenly, hand-tight.
  • Tighten all screws evenly to the specified torque. see. Check list below.
  • Check gap dimensions. Check list below.

Checklist

  • The clamping ring must be matched to the hose used
     
  • The distance between the clamping ring and the clevis part should be 7 mm
     
  • The screws should be hand-tightened.
    This is possible with hose diameters

    -> 52 mm with 20 Nm tightening torque,

    -> 76 mm + 90 mm diameter with 40 Nm tightening torque,

    -> 102 mm + 110 mm with 50 Nm tightening torque,

    -> 127 mm with 60 Nm tightening torque

    -> 152 mm with 80 Nm tightening torque

 

  • After assembly, the gap dimensions must be checked!
    The maximum distance between the segments is for hose diameters: 

    -> 52 mm + 76 mm > max. 2 mm gap dimension

    -> 90 mm + 102 mm + 110 mm > 3 mm gap dimension

    -> 127 mm > 4 mm gap dimension

    -> 152 mm > 5 mm

Request a callback now.
We will be happy to advise you.