Checklist

  • The clamping ring must be matched to the hose used
     
  • The distance between the clamping ring and the clevis part should be 7 mm
     
  • The screws should be hand-tightened. This is possible with hose diameters

-> 52 mm with 20 Nm tightening torque,

-> 76 mm + 90 mm diameter with 40 Nm tightening torque,

-> 102 mm + 110 mm with 50 Nm tightening torque,

-> 127 mm with 60 Nm tightening torque

-> 152 mm with 80 Nm tightening torque

 

  • After assembly, the gap dimensions must be checked! The maximum distance between the segments is for hose diameters: 

-> 52 mm + 76 mm > max. 2 mm gap dimension

-> 90 mm + 102 mm + 110 mm > 3 mm gap dimension

-> 127 mm > 4 mm gap dimension

-> 152 mm > 5 mm